fbpx
  • 01
  • 03
  • 01
  • 03

VenturiVent Plus

 

The low-profile, shingle-over look of VenturiVent Plus creates a clean, uncluttered roofline. It installs on the peak of the roof allowing exhaust ventilation along the entire ridge -- end-to-end.

With a 12" width, matching shingles can be installed over the vent, allowing the vent to appear almost invisible from the ground.

 

 Miami-Dade Approved

Description

create a clean, unclutterd roofline. 

 The low-profile, shingle-over look of VenturiVent Plus creates a clean, uncluttered roofline. It installs on the peak of the roof, allowing exhaust ventilation along the entire ridge -- end-to-end. With a 12" width, matching shingles can be installed over the vent, allowing the vent to appear almost invisible from the ground.

 

VenturiVent Plus features an external baffle that maximizes airflow performance and helps protect the attic from weather infiltration. It’s also designed for easy installation. Factor in the aesthetic advantages of a low-profile ridge vent and it’s easy to see why VenturiVent Plus is the vent of choice by roofing professionals

Includes a bag of nails.

 

VenturiVent

 

 

The low-profile, shingle-over look of VenturiVent Plus creates a clean, uncluttered roofline; and the vent performs better than other types of exhaust vents which are a lot more noticeable on the roof.

 

 

 

 

VenturiVent Plus

 

RELATED DOCUMENTS

 

Features

Product Features

  • Exceptional airflow. An external baffle creates low pressure over the vent openings to "pull" air from the attic. VenturiVent Plus provides 18 square inches of net free area per linear foot.

  • Advanced weather protection. The external baffle deflects wind and weather over the vent to help protect the attic from rain and snow infiltration.

  • Easy Installation. VenturiVent Plus has pre-printed slot guides for truss or ridge pole construction. Pre-drilled nailing holes are designed to assure proper nailing. The vent is pre-formed to a 4/12 pitch, and fits pitches from 3/12 to 16/12.

  • Limited Lifetime Warranty and 5-year Replacement Plus™ Protection. Provides peace of mind for the homeowner and installer.

  • Includes nails. VenturiVent Plus with nails has 30 3-inch ring shank, galvanized roofing nails bagged and taped to each 4-foot piece inside the carton. Installers will not have to hassle with removing nails that are snapped along the side of the vent prior to fastening.

Specifications

SPECIFICATIONS

When installed properly, all Air Vent products mentioned here comply with the net free area requirements of nationally recognized model codes, including those written by the International Code Council. In addition, the vents have product evaluation approvals from Dade County, Florida, ICC and TDI.

Please call 1-800-AIR-VENT to obtain code body information for a particular Air Vent product.

Here's an overview of the specifications for Air Vent's complete line of ridge ventilation products.

View the wide range of colors in which our products are available in our pdf color chart.

 

Product Model Description Colors Size Net Free Area

ShingleVent II SHFV,
12" wide
Shingle-over
ridge vent
Black


4' 18 sq. in. per ft.
ShingleVent® II with Nails SHFVBLN 12” Filtered Shingle-over Ridge Vent with Nails Black 4' 18 sq. in. per ft.

ShingleVent II-9 SHFV9CC,
9" wide
Shingle-over
ridge vent
Charcoal 4' 16 sq. in. per ft.

ShingleVent II-9A CLASH9CC,
9" wide
Shingle-over
ridge vent
Charcoal 4' 16 sq. in. per ft.

RidgeHawk Rolled Ridge Vent
with Nails
RH20 11" Wide
20' Long

Black 20' 15 sq. in. per ft.

Peak Performer I PPI 12” Shingle-over Rolled Ridge Vent with Nails Black 28’ 12 sq. in. per ft
Peak Performer II PPII 12” Filtered Shingle-over Rolled Ridge Vent with Nails Black 28’ 12 sq. in. per ft

VenturiVent Plus™ with Nails
VVPN Shingle-over ridge vent
with a bag of 30 3-inch ring shank nails taped to each 4-foot piece.
Black 4' 18 sq. in. per ft.
VenturiVent Roll VVR20 12” Shingle-over Rolled Ridge Vent Black 20’ 12 sq. in. per ft.

Continuous Unfiltered Ridge Vent        RV8000 Aluminum Ridge Vent Brown,
Black
8'  
End Plug FVL104 CRV End Plug Black    
           

 

 

Air Vent Color Chart

Air Vent Color Chart

Download PDF Download a PDF version of our color chart

 

THE SIMPLE MATHEMATICS OF A BALANCED RIDGE VENTILATION SYSTEM

 

  • According to most building codes, you need 1 square foot of ventilation for every 150 square feet of attic floor space.
  • For new home construction that includes a vapor retarder, the minimum is 1 square foot of ventilation for every 300 square feet of attic floor space.
  • If your vents are split between ridge vents and intake vents, the minimum requirement is also 1 square foot of ventilation for every 300 square feet of attic floor space.

 

To determine how many feet of net free area you need, use this formula:

Square feet of attic floor space

300
= Square feet of net free area needed
For example:    
1500 square feet of attic floor space

300
= 5 square feet of free are a needed

 

To determine how many feet of ShingleVent® II, Multi-Pitch FilterVent® or VenturiVent Plus™ you need, use this formula:
1/2 net free area x 144 ÷ 18 = feet of ridge vent needed
For example: 2.5 (based on net free area of 5 square feet) x 144 ÷ 18 = 20 feet of ridge vent needed
To determine how many feet of Air Vent soffit vents you need, use this formula:
1/2 net free area x 144 ÷ 9 = feet of soffit vent needed
For example: 2.5 (based on net free area of 5 square feet) x 144 ÷ 9 = 40 feet of soffit vent needed
The following charts may be used to:
1. Determine how much net free area is needed to satisfy FHA requirements.
2. Balance your ridge vent system.

 

DETERMINING VENTILATION REQUIREMENTS

 

Attic Square
Footage
Min. Net Free Area Required
(if balanced between intake and exhaust)
Min Length
of Ridge
1200
1500
1800
2100
2400
2600
3000
3300
4'
5'
6'
7'
8'
9'
10'
11'
576"
720"
864"
1008"
1152"
1296"
1440"
1584"
16'
20'
24'
28'
32'
36'
40'
44'

 

Note: ShingleVent II and Multi-Pitch FilterVent provide 18" of net free area per linear foot.

 

INSTALLING A BALANCED RIDGE VENT SYSTEM

 

  • Measure the square footage of the attic (length x width).
  • Measure the length of the ridge.
  • Refer to the chart above for required net free area and minimum length of ridge for attic square footage.
  • Note: In most cases, the length of the ridge balanced with the same net free area of intake vents will satisfy FHA minimum standards and most building codes.
  • Use the chart below to calculate the amount of intake vents that should be installed to balance your ridge vent system.
  • Always install ridge vents from end to end across the entire ridge for best appearance and to provide maximum ventilation area.
  • Hip roofs, dormers and T- or L-shaped roofs may require a specially designed ventilation system. For information, request a copy of Air Vent's Principles of Attic Ventilation.See Contact Us.

 

Balancing Your Ridge Vent System

Length of Ridge Linear Feet of
Continuous Soffit Vent
Number of Undereave Vents
16" x 8" 16" x 6" 16" x 4"
15' 30 5 6 10
20' 40 6 9 13
30' 60 10 13 19
40' 80 13 17 26
50' 100 16 21 32
60' 120 19 26 39
70' 140 23 30 45
80' 160 26 34 51
90' 180 29 39 58

Models

Models

VenturiVent Plus VVPN (with nails)

This shingle-over ridge vent is black and comes in 4 foot lengths.

 

Warranty

WARRANTY

Learn about warranty coverage, transferability, limitations, other conditions and customer responsibilities.

 

Read the full warranty and the list of eligible products.

 

For Warranty information and questions, please contact us at: warranty@gibraltar1.com 

 

Warranty Download Download Full Air Vent Warranty Information

 

Limited Warranty
The Air Vent Product that you have purchased has a limited warranty from the date of purchase against defects in workmanship and materials. The length of the warranty varies by product. Please see attached chart for details. This warranty does not cover any labor costs, including those required for field repair or replacement or removal of any allegedly defective part.

 

Proof of purchase is required when requesting warranty service.
The original purchaser must present a sales receipt or other document that establishes proof of purchase.
Please do not ship your fan or any fan parts to Air Vent unless requested to do so.

 

Limitations
Air Vent shall not be liable for, and this warranty does not apply to, any failure, defect or damage resulting from or connected with misuse, abuse, neglect or improper handling or staging , or installation not in strict adherence to Air Vent’s written instructions; impact of foreign objects, fire, flood, earthquake, lightning, hurricane, hail, tornado or other violent storms or other act of God; or defects in failure of or damage caused by materials used as roofing base over which the product is installed or by movement, distortion, cracking or settling of walls or the foundation of the building.

Air Vent reserves the right to discontinue or modify any of its products including color, and shall not be liable as a result of such discontinuation or modification, nor shall Air Vent be liable in the event replacement material may vary in color in comparison to the original product as a result of normal weathering. If Air Vent replaces any product under this warranty, it may substitute products designated by Air Vent to be of comparable quality or price range in the event the product initially installed has been discontinued or modified.

 

Replacement Plus™ Protection
Products are covered by Replacement Plus™ protection (see attached for applicable products) for a period of time (varies by product) provided that the product has been installed in strict accordance with Air Vent’s written installation instructions. Under this warranty feature, Air Vent, at no charge, will replace any product found to be defective during the Replacement Plus™ period as long as proof of purchase is submitted to Air Vent (Replacement Plus™ period begins when the product installation is completed). Air Vent’s maximum liability under Replacement Plus will be equal to the reasonable cost to replace the defective product, including labor.

In instances in which Air Vent, according to the terms of this warranty, has agreed to pay the cost of labor required to replace a defective intake vent, Air Vent will provide reimbursement only upon receipt of a copy of the contractor’s invoice or other written evidence of the completion of the work which Air Vent, at its sole discretion, deems acceptable.

 

Transferability
Provided that the products covered by this warranty have been installed in strict accordance with the Air Vent Inc. written installation instructions and in accordance with all local codes and standards, including those pertaining to fire-rated construction, Air Vent warrants to the original purchaser or first subsequent owner of the property that the product is free from manufacturing defects for the described length below from the date of purchase. If there is a change in ownership, the warranty may be transferred by the original purchaser of the product to the new owner (first subsequent owner) under the terms and conditions of this warranty.

 

Motor Replacements
The electrical motor is to be used solely as a direct replacement for a motor of the same model in an Air Vent, Inc, power attic ventilator. Using the motor in any other product could result in electrical shock and/or fire, which may cause property damage, serious injury or even death. Any motor replacement should be installed by a qualified licensed electrician in accordance with local, state and national electrical codes and standards. Make sure that power to the unit has been completely turned OFF at the breaker before approaching or inspecting the power attic ventilator or installing the replacement motor.

 

Other Conditions
This warranty is expressly in lieu of all other oral or written warranties, liabilities or obligations of Air Vent. Pertinent state law shall control for what period of time subsequent to sale a consumer/homeowner may seek a remedy pursuant to the implied warranty of merchantability or fitness for a particular purpose. In no event shall Air Vent be liable for consequential or incidental damages of any kind, including any damage to the building, its contents or any persons therein, resulting from the breach of any warranty set forth herein, unless exclusion of these types of damages are specifically prohibited by state law. No field representative of Air Vent or any distributor or dealer is authorized to make any change or modifications to this warranty. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

 

The following warranty is effective 3/26/2021.


 Product Model Number  Warranty  Replacement Plus Protection
 ShingleVent ®II ridge vent (12", 9", Class A 9")   Limited Lifetime Warranty 5 year Replacement Plus™ protection

 Peak Performer™ I & II Rolled ridge vent   Limited Lifetime Warranty 5 year Replacement Plus™ protection

 The Edge™ Vent   Limited Lifetime Warranty 5 year Replacement Plus™ protection

 Hip Ridge® Vent   Limited Lifetime Warranty 5 year Replacement Plus™ protection

 VenturiVent™ Plus ridge vent and rolled ridge vent   Limited Lifetime Warranty 5 year Replacement Plus™ protection

ATTIC-AIRE™ ALL SEASONS™ Filtered Ridge Vent and Roll Vent   Limited Lifetime Warranty 5 year Replacement Plus™ protection

RidgeHawk™ Rolled ridge vent with nails RH20 Limited Lifetime Warranty  

ShadowHawk® Low Profile Vent LPG72 Limited Lifetime Warranty 5 year Replacement Plus™ protection

Roof Mount Power Vent ASRHP, SV3000, HE15WW Limited Lifetime Warranty 5 year Replacement Plus™ protection

Roof Mount Power Vent RV26, RV28, PC12 10 Year Limited Warranty 5 year Replacement Plus™ protection

Gable-Mount Power Vent APG, APGH Limited Lifetime Warranty 5 year Replacement Plus™ protection

Gable-Mount Power Fans (WCGB)- with Thermostat   Limited Lifetime Warranty 5 year Replacement Plus™ protection

Gable-Mount Power Fans (model WCGA)   5 Year Limited Warranty 5 year Replacement Plus™ protection

Roof Mount Solar Power Fans NPSP8WW, SC8BL 5 Year Limited Warranty 2 year Replacement Plus™ protection

Gable Mount Solar Power Fans NPSG8 5 Year Limited Warranty 2 year Replacement Plus™ protection

 Whole-House Fans   10 Year Limited Warranty 5 year Replacement Plus™ protection

Roof Louvers/Static Vents   5 Year Limited Warranty  

Airhawk® Wind Turbines TIB, TOB series    

Type B Gas Vent Cap PTOP Series 5 Year Limited Warranty  

Automatic Foundation Vent   5 Year Limited Warranty  

Powered Foundation Vent   5 Year Limited Warranty  

Low Voltage Foundation Vent Series 5 & 6, Radon 5 Year Limited Warranty  

Roof Mount Solar Power Fans 9010TR, 9025TR 5 Year Limited Warranty on Fan Motors 20 Year Limited on Solar Panel, Fan Housings

Gable Mount 20 Watt Solar Fan 1125APV 5 Year Limited Warranty on Fan Motors 20 Year Limited on Solar Panel, Fan Housings

Skylight Tubes 2214ST-LK 10 Year Limited Warranty  

Archived Products
 Product Model Number  Warranty  Replacement Plus Protection
ShingleVent ®II ridge vent 7", Class A 7"   Limited Lifetime Warranty 5 year Replacement Plus™ protection

Ridge Vent 20’ MRV20 Limited Lifetime Warranty  

Attic Aire™ Wind Turbines (WT series)   5 Year Limited Warranty  

Roof Mount Solar Power Fans 9910TR, 9920TR, 9930TR 5 Year Limited Warranty on Fan Motors 20 Year Limited on Solar Panel, Fan Housings

Gable Mount 20 Watt Solar Fan 1020APV 5 Year Limited Warranty on Fan Motors 20 Year Limited on Solar Panel, Fan Housings

U.S. Sunlight Solar Controller SC20 1 Year Limited Warranty on Unit, Remote  

Skylight Tubes 1914ST, 2114ST 10 Year Limited Warranty  

 

Product Photos

PRODUCT PHOTOS

Click an image to enlarge:

Success Stories

Success Story - VenturiVent Plus (with help from the Air Vent App)

 

Hometown Roofing
Address: 13316 Millard Avenue
Omaha, NE 68137
Phone: Office: 402-896-3639; Cell: 402-681-2180
Website: www.hometownroofing.com
Email: brett@hometownroofing.com

 

“The homeowner asked us for a bid for a roof replacement due to damage from a hail storm. While walking the perimeter of the house, my salesman noticed that there were only a few soffit vents installed and they were only on one side of the house. This prompted him to open the Air Vent app and calculate how much intake and exhaust that a house/attic of this size should have. The existing roof had roughly 60 ft. of ridge length available and a rolled ridge vent installed. My salesman determined this house would actually require a ridge vent that had increased airflow (that is, more Net Free Area per linear foot) instead of the rolled ridge vent due to the length of ridge present.

He also found that the home needed an additional 13 16” x 8” rectangular undereave vents to balance the intake with the exhaust. Finally, upon removing one of the existing intake vents, he found that the insulation was sandwiched between the roof deck and the exterior wall of the house that extended up into the soffit area. Essentially, this house had no intake at all. We fixed the issues by cutting in the additional undereave vents, adding attic insulation baffles in most of the rafter bays, and installing Venturi Vent plus ridge vent. The homeowner has a beautiful new roof that ventilates properly for the first time ever. ”
 – Brett Huizenga, Owner, Hometown Roofing, Omaha, NE

 

Editor’s Note: The Air Vent app is a quick, easy way to confirm if the attic has a balanced amount of intake and exhaust vents based on the attic’s square footage (length x width, floor of the attic). If you do not know the actual attic square footage, an acceptable Plan B measurement is the footprint of the house. The app is available free for both IOS and Android devices. 

 

Click an image to enlarge:

 

Image 1 & 2) VenturiVent Plus ridge vent installed with 18 square inches of Net Free Area per linear foot.
Image 3) Removing the undereave vent during the attic/roof inspection revealed blocked intake. (low)
Image 4) After the correct quantity of 8” x 16” rectangular undereave vents were installed.


 

 

Videos

Smoke House Attic Airflow Demonstration at the International Roofing Expo

A real-time demonstration of the difference between a balanced attic ventilation system and unbalanced. This is exactly why intake airflow is so critical. And see for yourself the Bernoulli Effect when the wind hits the external baffle on ShingleVent II ridge vent. Wow!

Video courtesy of Sara Klindtworth, owner of Solid Roofing NW in Albany, Oregon.

 

 

 

 

Product Categories
Exhaust Vents Solar Attic Fans Intake Vents Foundation Vents Whole House Fans Bath or Dryer Vents Skylight Tubes
 
Air Vent Contractor LocatorOur exclusive Contractor Locator will allow you to find contractors in your area who can assist with Air Vent product installation—including solar attic fans and skylight tubes. Click the link below to register and get started.

 

Search for Contractors
Save
Cookies user preferences
We use cookies to ensure you to get the best experience on our website. If you decline the use of cookies, this website may not function as expected.
Accept all
Decline all
Functional
By using this website, you agree to our use of cookies. We use cookies to provide you with a great experience and to help our website run effectively.
Analytics
Tools used to analyze the data to measure the effectiveness of a website and to understand how it works.
Google Analytics
Accept
Decline