Gable-Mount Power Attic Vents

It's electric powered and uses a thermostat and humidistat control to help prevent heat and moisture buildup inside the attic.

Installed in the gable end of the house, the Gable-Mount Ventilator operates 30% more quietly than comparable units and with 35% greater efficiency. What's more, since many homes already feature a gable or vent, it may not be necessary to cut a hole to install the gable-mount ventilator.

 

Description

electric gable 01Installed in the gable end of the house, the Gable-Mount Power Vent uses a thermostat to help prevent heat buildup and a humidistat ("Plus" models only) to fight moisture buildup inside the attic.

It operates 30% more quietly than comparable units and with 35% greater efficiency. What's more, since many homes already feature a gable or gable vent, it may not be necessary to cut a hole to install the gable-mount ventilator.

 

Gable Shutters

 

A shutter (Model SHT15W, sold separately) opens automatically when the fan turns on to allow the unit to exhaust efficiently.

The shutter can be painted to match the home’s exterior.A gable-mounted power fan is installed in the gable end of the attic. Some homes already have gable end vents or louvers there, making it easy to install a powered fan at that location.

 

 

RELATED DOCUMENTS

 

Features

  • Feature patented rings instead of solid-steel housing, which pull more air
  • Operate 30% quieter and 35% more efficiently than comparable units
  • Automatic shutter available in white, but can be painted to coordinate with home's exterior

 

 

Specifications

SPECIFICATIONS

HOW TO SIZE POWER VENTS?
Power vents are rated in CFM—cubic feet of air moved per minute. The higher the CFM, the more powerful the vent and the more air exchanges per hour it provides. To determine the minimum CFM required, multiply the attic square footage by 0.7. For example:


1500 square feet x 0.7 = 1050 CFM
Thus, a fan rated at least 1050 CFM is needed


HOW MUCH INTAKE VENTILATION?
Just like any exhaust vent power vents need intake airflow to perform properly. To calculate how much intake the power vent needs simply divide the fan's CFM capacity by 300 and then convert that number to square inches.

  CFM of Power Vent

300
= Square feet of
intake net free area needed
x 144 = Square inches of
intake net free area needed
  For example:    
  1050 CFM

300
= 3.5 Square feet of
intake net free area needed
x 144 = 504 Square inches of
intake net free area needed

AIR VENT POWER VENTS

 

  Color Model Part No. Pcs/Ctn Ctns/Pallet
Power Cool Plus Power Attic Ventilators          
Roof-Mount Metal with pre-wired Humidistat/Thermostat
1500 CFM
Gray PC15GR 97707 1 30
  Weatherwood PC15WW 97702 1 30
  Brown PC15BR 97703 1 30
  Black PC15BK 97704 1 30
           
  Gray ASRHPGR 53850 1 30
  Weatherwood ASRHPWW 53849 1 30
  Brown ASRHPBR 53848 1 30
  Black ASRHPBK 53847 1 30
           
Roof-Mount Metal with pre-wired Thermostat 1500 CFM Brown SV3000BR 53853 1 30
  Weatherwood SV3000WW 53854 1 30
  Black SV3000BK 53862 1 30
           
           
Roof-Mount Metal with pre-wired Humidistat/Thermostat
1170 CFM
Gray  PC12GR  97711  1 30 
  Weatherwood  PC12WW  97712  1 30 
  Brown  PC12BR  97713  1 30 
  Black  PC12BK  97714  1 30 
           
Power Cool Power Attic Ventilators          
Roof-Mount Metal with Thermostat 1320 CFM Gray BR28GR 97677 1 30
  Weatherwood BR28WW 97679 1 30
           
  Gray RV28GR 53833 1 30
  Weatherwood RV28WW 53832 1 30
  Brown RV28BR 53831 1 30
           
Roof-Mount Metal with Thermostat 1170 CFM Gray BR26GRMT 97677 1 30
  Weatherwood BR28WW 97679 1 30
           
  Gray RV26ML 53830 1 30
  Weatherwood RV26WWMT 53829 1 30
  Brown RV26BRMT 53827 1 30
           
Roof-Mount Plastic with Thermostat 1170 CFM Gray BR26GR 97673 30 
  Brown BR26BR 97675  30 
  Black BR26BK 97674  30 
           
  Gray RV26GR 53828 1 30
           
 Gable-Mount Power Attic Ventilators          
Gable-Mount with Humidistat/Thermostat 1620 CFM   APGH  53320  1 64
Table-Mount with Thermostat 1620 CFM   APG 53316 1 64
Gable-Mount with Thermostat only 1320 CFM   WCGB  53319  1 64
Gable-Mount with Thermostat 1050 CFM   WCGA 53315 1 64
Solar Power Gable-Mounts    NPSG8  53560  1 60
Automatic Gable Shutter (white only)   SHT15W  54703  1 160 
           
Solar Powered Attic Ventilators          
30-Watt Solar Roof-Mount with Solar Controller Humidistat/Thermostat Black AV9930TRS 97326 1 18
15-Watt Solar Roof-Mount with Solar Controller Humidistat/Thermostat Black AV9915TRS 97325 1 18
SolarCool Roof-Mount Metal Black SC8BL 97310 1 18
Roof-Mount Metal w/separate Solar Panel  Weatherwood NPSP8WW  53510 1 18

 

 

 

 

 

 

 

Models

WCGA -- Quality Gable-Mount
With automatic thermostat
1050 CFM for attics up to 1500 sq. ft.
Five-year limited warranty

 

WCGB -- Premium Gable-Mount
With automatic thermostat
1320 CFM for attics up to 1900 sq. ft.
Ten-year limited warranty and 5-year Replacement Plus™ protection

 

APG -- Premium Gable-Mount
With automatic thermostat
1620 CFM for attics up to 2300 sq. ft.
Lifetime warranty

 

APGH -- Premium Plus Gable-Mount
With automatic thermostat and humidistat
1620 CFM for attics up to 2300 sq. ft.
Lifetime limited warranty and 5-year Replacement Plus™ protection

 

Gable ShuttersAutomatic Shutter (SHT15W)

  • Model #SHT15W
  • Plastic
  • Sold in the color white only but it can be painted to match a home’s exterior
  • Automatically opens when the power fan is running and then closes when the fan is not running

 

 

 

Warranty

WARRANTY

Learn about warranty coverage, transferability, limitations, other conditions and customer responsibilities.

Read the full warranty and the list of eligible products.

 

For Warranty information and questions, please contact us at: warranty@gibraltar1.com

 

Limited Warranty
The Air Vent Product that you have purchased has a limited warranty from the date of purchase against defects in workmanship and materials. The length of the warranty varies by product. Please see attached chart for details. Any part believed to be defective must be returned to the factory (Air vent, Inc., 4117 Pinnacle Point Dr, Suite 400, Dallas, Texas 75211) freight prepaid. If found to be defective following examinations, any defective part will be replaced free of charge and returned freight prepaid. This warranty does not cover any labor costs, including those required for field repair or replacement or removal of any allegedly defective part. Limitations

Air Vent shall not be liable for, and this warranty does not apply to, any failure, defect or damage resulting from or connected with misuse, abuse, neglect or improper handling or staging , or installation not in strict adherence to Air Vent’s written instructions; impact of foreign objects, fire, flood, earthquake, lightning, hurricane, hail, tornado or other violent storms or other act of God; or defects in failure of or damage caused by materials used as roofing base over which the product is installed or by movement, distortion, cracking or settling of walls or the foundation of the building.

Air Vent reserves the right to discontinue or modify any of its products including color, and shall not be liable as a result of such discontinuation or modification, nor shall Air Vent be liable in the event replacement material may vary in color in comparison to the original product as a result of normal weathering. If Air Vent replaces any product under this warranty, it may substitute products designated by Air Vent to be of comparable quality or price range in the event the product initially installed has been discontinued or modified.

Replacement Plus™ Protection
Products are covered by Replacement Plus™ protection (see attached for applicable products) for a period of time (varies by product) provided that the product has been installed in strict accordance with Air Vent’s written installation instructions. Under this warranty feature, Air Vent, at no charge, will replace any product found to be defective during the Replacement Plus™ period (Replacement Plus™ period begins when the product installation is completed). Air Vent’s maximum liability under Replacement Plus will be equal to the reasonable cost to replace the defective product, including labor. In instances in which Air Vent, according to the terms of this warranty, has agreed to pay the cost of labor required to replace a defective intake vent, Air Vent will provide reimbursement only upon receipt of a copy of the contractor’s invoice or other written evidence of the completion of the work which Air Vent, at its sole discretion, deems acceptable.

Transferability
Provided that the products covered by this warranty have been installed in strict accordance with the Air Vent Inc. written installation instructions and in accordance with all local codes and standards, including those pertaining to fire-rated construction, Air Vent warrants to the original purchaser or first subsequent owner of the property that the product is free from manufacturing defects for the described length below from the date of purchase. If there is a change in ownership, the warranty may be transferred by the original purchaser of the product to the new owner (first subsequent owner) under the terms and conditions of this warranty. Motor Replacements:

The electrical motor is to be used solely as a direct replacement for a motor of the same model in an Air Vent, Inc, power attic ventilator. Using the motor in any other product could result in electrical shock and/or fire, which may cause property damage, serious injury or even death. Any motor replacement should be installed by a qualified licensed electrician in accordance with local, state and national electrical codes and standards. Make sure that power to the unit has been completely turned OFF at the breaker before approaching or inspecting the power attic ventilator or installing the replacement motor. art #18913

Other Conditions
This warranty is expressly in lieu of all other oral or written warranties, liabilities or obligations of Air Vent. Pertinent state law shall control for what period of time subsequent to sale a consumer/homeowner may seek a remedy pursuant to the implied warranty of merchantability or fitness for a particular purpose. In no event shall Air Vent be liable for consequential or incidental damages of any kind, including any damage to the building, its contents or any persons therein, resulting from the breach of any warranty set forth herein, unless exclusion of these types of damages are specifically prohibited by state law. No field representative of Air Vent or any distributor or dealer is authorized to make any change or modifications to this warranty. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

The following warranty is effective 6/20/2014.

 Product  Warranty  Replacement Plus Protection
 ShingleVent ®II ridge vent (12", 9", 7", Class A 9" and 7") Limited Lifetime Warranty 5 year Replacement Plus™ protection

 Peak Performer™ I & II Rolled ridge vent Limited Lifetime Warranty 5 year Replacement Plus™ protection

 Multi-Pitch FilterVent® ridge vent Limited Lifetime Warranty 5 year Replacement Plus™ protection

 The Edge™ Vent Limited Lifetime Warranty 5 year Replacement Plus™ protection

 Hip Ridge® Vent Limited Lifetime Warranty 5 year Replacement Plus™ protection

 VenturiVent™ Plus ridge vent Limited Lifetime Warranty 5 year Replacement Plus™ protection

 VenturiVent™ Rolled ridge vent Limited Lifetime Warranty 5 year Replacement Plus™ protection

 ATTIC-AIRE™ ALL SEASONS™ Filtered Ridge Vent and Roll Vent Limited Lifetime Warranty 5 year Replacement Plus™ protection

 Power Cool Plus™ Power Attic Ventilator- model PC15 Limited Lifetime Warranty 5 year Replacement Plus™ protection

 Power Cool Plus™ Power Attic Ventilator- model PC12 10 Year Limited Warranty 5 year Replacement Plus™ protection

 Power Cool™ Power Attic Ventilator- model BR28 10 Year Limited Warranty 2 year Replacement Plus™ protection

 Power Cool™ Power Attic Ventilator- model BR26 5 Year Limited  2 year Replacement Plus™ protection

 Solar Power Fan- (models NPSP8WW, SC8BL, NPSG8) 5 Year Limited Warranty 2 year Replacement Plus™ protection

 Gable-Mount Power Fans (APG, APGH)- with Humidistat Limited Lifetime Warranty 5 year Replacement Plus™ protection

 Gable-Mount Power Fans (WCGB)- with Thermostat 10 Year Limited Warranty 5 year Replacement Plus™ protection

 Gable-Mount Power Fans (model WCGA)- Solar  5 Year Limited Warranty 2 year Replacement Plus™ protection

 Whole-House Fans 10 Year Limited Warranty 5 year Replacement Plus™ protection

 Roof Mount Power Vent (ASRHP, SV3000) Limited Lifetime Warranty 5 year Replacement Plus™ protection

 Roof Mount Power Vent (RV28) 10 Year Limited Warranty 5 year Replacement Plus™ protection

 Roof Mount Power Vent (NPSP8WW, SC8BL, RV26 series) 5 Year Limited Warranty 2 year Replacement Plus™ protection

 Automatic Foundation Vent 5 Year Limited Warranty  

 Heavy Duty Automatic Foundation Vent 5 Year Limited Warranty  

 Powered Foundation Vent 5 Year Limited Warranty  

 Ridge Vent 20’ Limited Lifetime Warranty  

 Airhawk® Wind Turbines (TIB, TOB series) Limited Lifetime Warranty  

 Attic Aire™ Wind Turbines (WT series) 5 Year Limited Warranty  

 Low Voltage Foundation Vent (Series 5 & 6, Radon) 5 Year Limited Warranty  

 Solar Power Fan (AV9915TRS) 10 Year Limited Warranty 5 year Replacement Plus™ protection

 Solar Power Fan (AV9930TRS) Limited Lifetime Warranty 5 year Replacement Plus™ protection

 Skylight Tubes (1914ST, 2114ST) 10 Year Limited Warranty  

 

Product Photos

PRODUCT PHOTOS

Click an image to enlarge:

 

 

 

Product Categories
Exhaust Vents Solar Attic Fans Intake Vents Foundation Vents Whole House Fans Bath or Dryer Vents Skylight Tubes
 
Air Vent Contractor LocatorOur exclusive Contractor Locator will allow you to find contractors in your area who can assist with Air Vent product installation—including solar attic fans and skylight tubes. Click the link below to register and get started.

 

Search for Contractors